Logo Quantec industrial floors
The specialist company for the repair and refurbishment of
industrial and commercial floors, storage and order picking areas
  • Imprint
  • Data protection
de
en
pl
fr
it
cs
ru
sv
Contact
  • Home
  • The company
  • Jobs
  • Lexicon
  • Contact
  • Additional Services
    • Swap Body Parking Spaces
    • Floor Sealants
    • Soil Sealing
    • Floor Markings
    • Installation of Induction Loops
  • Expansion joints
    • Heavy-duty profiles
    • Construction Joints
  • Soil remediation
    • Industrial Floor Remediation
    • Crack Repair
    • Structural Rehabilitation
  • Industrial floors
    • Commercial Flooring
    • Chemical-Resistant Industrial Flooring
    • Non-slip flooring
    • Fast-curing industrial floor
  • Coatings
    • Industrial Floor Coatings
    • Epoxy Resin Coating
    • Acrylic resin coating
    • Polyurethane coating
    • WHG Coating
    • Conductive coating
Expansion joints
Coatings
Industrial floors
Industrial floors
You are here:
  • Home
  • Soil remediation
  • Structural Rehabilitation

Spot Repair - Quickly Fix Damaged Areas in Industrial and Logistics Floors

Quantec Industrieböden® GmbH performs floor renovation on existing industrial, commercial, and logistics facilities—with precision, durability, and a clear approval process that minimizes disruption to ongoing operations.
Reminder Regarding Release Planning
Request a Damage Inspection
Background
Background
Localized spalling, flaking, and damaged or weakened edge areas are typical causes of recurring problems in traffic lanes and crossings. Spot repairs stabilize these hotspots before damage spreads and closed areas grow larger. Depending on the available time window, repairs are organized so that traffic routes remain usable in a controlled manner.

Why Quantec?

10-Year Warranty

Damaged areas in industrial floors require quick and durable solutions. With our many years of experience and our high-strength, fast-curing mortar systems, we can repair damaged areas within a few hours. This minimizes downtime and ensures that the affected areas are quickly restored to service.
Quantec Industrial Floor Restoration

Targeted Rather Than Widespread

Resolve hotspots without unnecessarily blocking the entire area.

Short downtime windows can be utilized

Implementation in coordinated phases, including during off-peak hours.

EP / AC / PU Systems

Select based on load profile, wear, and desired time to return to service.

In-House Machinery

No subcontractors, clear processes, reproducible results.

When Column Rehabilitation Is the Most Cost-Effective Solution

Not every type of damage requires a complete surface restoration. Spot repair is advisable when the problem is localized but has an immediate impact on operations.

Typical causes

  • Damage in traffic lanes, aisleways, or picking zones
  • Spalling at edges, transitions, or near joint edges
  • Localized damage in door and ramp areas
  • Localized exposure to substances (e.g., oil or cleaning agents) causing surface degradation
  • Recurring minor repairs at the same location (indicating a problem in the edge zones)
Structural Rehabilitation

Structural rehabilitation with seamless integration into the existing building

Quantec does not perform “cosmetic” repairs on damaged areas; instead, it repairs them in such a way that the repaired area can withstand loads and does not crack again at the edges. The key factors are the precise demarcation of the repair area, a stable edge zone, and a system design that is suited to the intended use.

Typical Project Workflow 1

Marked damaged areas and old repairs in a commercial floor

Assessment

Rectangularly cut and chiseled-out damaged areas in the commercial floor

Chiseling

Renovated and sealed repair areas flush with the commercial floor

Renovated and sealed

Typical Project Workflow 2

Small areas of damage on the gym floor next to the bumper guard, each cut out individually

Assessment

Damaged areas that have been chiseled out and the path of the crack in the gym floor before backfilling

Prepared and chiseled out

Repaired damaged areas and cracks with sealed edges in the gym floor

Renovated and sealed

What Quantec's Column Rehabilitation Service Includes

Repair of Damaged Areas

  • Repair of cracks, spalling, and localized loss of load-bearing capacity
  • Stabilization of edge zones in traffic lanes and transitions
  • Restoring drivability in hotspots

Interfaces with Joints / Cracks / Profiles

  • Combine with crack repair if the edges of the cracks extend into the damaged area
  • Integration into expansion joint repair, if joint edges are the cause
  • Option: Heavy-duty profiles for mechanical reinforcement of edges

Surface stabilization (if necessary)

  • System configuration with EP, AC, or PU, depending on the application
  • Additionally: Sealing to reduce abrasion and dirt accumulation
  • Markings as an add-on when traffic routing needs to be adjusted

EP, AC, or PU—What Factors Determine the Choice?

Important: Quantec renovates existing floors. The company does not perform new construction work involving concrete/screed or click-system flooring. Asphalt surfaces are repaired, but not newly laid.
EP (epoxy resin)
Suitable for high mechanical stress and heavy-duty repair areas
AC (acrylic resin)
advantageous when very short turnaround times are required
PU (polyurethane)
recommended when more elastic material behavior or dynamic loading is a factor

Repair without unnecessarily disrupting the flow of materials

Renovations of workstations can often be scheduled in such a way that main pathways are preserved. The key is to plan based on traffic flow, not on “square footage.”

Practical Guidelines

  • Repair windows based on shift schedules and traffic patterns
  • Clear cordoning off of the zone with defined detours
  • Temporary solutions for safe crossings (if necessary)
  • Section-by-section reopening so that areas can be put back into use quickly
Request a Damage Inspection
Structural Rehabilitation

Where Structural Rehabilitation Is Used Most Frequently

Tire tracks from forklifts and pallet jacks

Transitions at gates, ramps, and crossings

Aisle sections with recurring point and rolling loads

Turning zones (e.g., near parking spaces and curbs)

Maintenance and workshop areas with local utility loads

Job Reorganization Process—Organized in a Transparent Manner

Close-up of the damaged area
You send photos, the location, and the use (lane, crosswalk, gate area). The goal is to prioritize quickly.
Define a redevelopment zone
The zone is delineated in such a way that peripheral areas are effectively incorporated and no new break-out edge is created.
Specify the system configuration
Select EP/AC/PU based on the load profile and the desired activation time.
Implementation and Approval
Implementation by our own team, followed by clear approval of the zone for operation.
Before
Afterward
Background
Background
Industry | Logistics | Commercial · Traffic Lanes & Hotspots · Predictable Closure Times · Stable Transitions

Types and Variations of Column Rehabilitation

Pothole Repair Using Reaction-Curing Resin Mortar
Operating PrincipleThe damaged area is clearly delineated, A load-bearing edge zone was created and rebuilt using a mortar system; the transition is flush/chamfered, to reduce shock loads
Typical UsesLanes, Intersections, Goal Lines, Recurring hotspots
DelimitationDo not “apply putty over crumbly surfaces”; the load-bearing area and geometry are crucial
Decision ParametersIndustry-specific fieldRelevance to Interpretation
Degree of interventionapprox. 15-80 mmdetermines integration and perimeter security
Edge ProfileChamfer/RadiusImpact Energy Management
Mortar SystemEP (Reserve) / MMA (Short Window)Release Time vs. Robustness
Traffic Profilemoderate to very highShock/impact loads dominate
Flatness Targetflush, without an edgeDrivability from Initial Release
Risk of Recurring Damagehigh with poor transitionsPrioritize transitional training
Chemical/Oil Contamination Hotspot (Media Zone) as Part of Structural Rehabilitation
Typical UsesLeakage points, Service Areas, Cleaning Stations
DelimitationWithout a media profile, “chemical-resistant” cannot be specified
Operating PrincipleThe contaminated zone is prepared technically as follows:, that adhesion and durability can be restored in the media profile; sealing details reduce the risk of infiltration
Decision ParametersIndustry-specific fieldRelevance to Interpretation
Medium/Concentrationcompany-specificSystem access is only available through this method
Exposure timeSplash contact to standingReserve Force/Advanced Training
Degree of contaminationsuperficial to deepIntervention and Blocking Logic
Surface finishlow-porosityLimit Infiltration
Transitionsflush, without a visible edgeNo new vulnerability
Maintenance Logiclocally reproducibleKeep hotspots repairable using a modular approach
Delamination/Hollow Layer Repair (Local Loss of Layer Bonding)
Typical UsesCoated surfaces with bubbles/peeling, Peripheral Areas, Repair History
DelimitationCosmetic surface repairs without structural restoration lead to rapid delamination
Operating PrincipleLoose/decoupled areas will be removed, The subgrade was stabilized and the bond was restored using a new system design
Decision ParametersIndustry-specific fieldRelevance to Interpretation
Extent of delaminationlocal to zonalDefine the repair area
Soil contaminationpossible (oil/chemicals)decides on pretreatment
Structural ConceptMortar + Topcoat / ResurfacingConsider the composite and the surface separately
Coating thicknessfunction-orientedNot “fat,” but just right
Cleaning regimenrelevantTopcoat Compatibility
Connection to Existing Infrastructurelow-porosity/flushAvoid entry paths and edges
Joint-Edge Repair in Wheel Load Lines
Typical UsesForklift Axles, Curves, Intersections, Chipped edges along joints
DelimitationFilling the joint alone does not resolve flank failure; start with the load-bearing flank, then joint function
Operating PrincipleDamaged joint edges are re-profiled and rebuilt to be highly durable; optionally combined with profile/edge protection
Decision ParametersIndustry-specific fieldRelevance to Interpretation
Flank damageFrom edge chipping to spallingDefine the intervention limit
Shear stresshigh when changing directionCheck the profile/edge protection
Connection Geometryload-stabilizedprevents further flaking
System SelectionEP/AC(MMA) per time slotBusiness logic controls materials
AddendumHeavy-duty profile availableMechanically decouple edge joints
ApprovalzonalTraffic Management During Construction
Structural Rehabilitation of potholes in asphalt (existing pavement) in traffic and maneuvering areas
DelimitationNo new asphalt will be laid; the goal is to restore functionality at critical points
Operating PrincipleLocal stabilization of asphalt surfaces through load-distributing islands/transition zones, to limit indentation and shear deformation
Typical UsesYard/Marshalling Areas, Adjustment Ranges, Outdoor Service
Decision ParametersIndustry-specific fieldRelevance to Interpretation
Deformation patternTrack groove/shear foldIsland-sized instead of micro-pad
Temperature/Summer Load CaserelevantShear Strength and Transition
Transition: Island ↔ Asphaltchamfered/flushPrevents edge chipping
System SelectionEP/PU/MMA (depending on the specific details)Time Window and Robustness
Entry on the outsideWater/DirtDensity/Edge Logic
RepairabilitymodularRecurring hotspots are manageable

Spot Repair of Industrial, Commercial, and Logistics Floors

Spot repair is a localized repair method used when damage occurs in specific areas but the surface as a whole remains usable. The technical decision is based on the damage mechanism (spalling, delamination, crack/joint edge failure, contamination), the load type (wheel load, point load, shear), and the joint geometry (flush, chamfered, profile-protected). In logistics and industry, repairs often fail not because of the material itself, but due to insufficient edge zone load-bearing capacity or poorly stabilized transitions. Quantec Industrieböden® GmbH performs spot repairs using EP, AC (MMA), and PU mortars; repairs to existing asphalt surfaces are carried out as restorations without the need to lay new pavement.
Quantec Industrial Floor Restoration

FAQ

Warehouse logistics
Material Handling
Food industry
Maintenance, Renovation, and Operation
Chemistry

Logistics & Warehousing

Manufacturing & Mechanical Engineering

Food & Hygiene

ESD & Special-Purpose Functional Surfaces

Chemistry/Media & WHG/AwSV

Request a Job Reassignment—with Clear Approval Criteria

Please send us details on the location of the damage, usage, and your preferred time frame. You will receive a detailed assessment and a recommendation for next steps.
Check for Damage & Request a Quote
File upload
The content of this page is intended to provide general information about Structural Rehabilitation and does not constitute project-specific technical planning or a guarantee of specific properties. Since specific requirements and results depend on individual on-site conditions, no liability is assumed for the accuracy of this information.

Why Act Now?

Repeated joint repairs usually result in higher long-term costs than a technically sound renovation of edge zones and transitions. A joint inspection provides clarity on priorities, closure periods, and a logical approach to sectioning.
Request joint check
Structural Rehabilitation
Conductive Coating
Structural Rehabilitation
Expansion joints
Structural Rehabilitation
Waterproofing
Structural Rehabilitation
Induction
Structural Rehabilitation
Industrial Floor
Structural Rehabilitation
Markings
Structural Rehabilitation
Crack Repair
Structural Rehabilitation
Heavy-duty profiles
Structural Rehabilitation
Sealing
Structural Rehabilitation
Acrylic resin coating
Structural Rehabilitation
Chemical-Resistant Floor
Structural Rehabilitation
Epoxy Resin Coating
Structural Rehabilitation
Commercial Flooring
Structural Rehabilitation
Industrial Floor Coatings
Structural Rehabilitation
Industrial Floor Coatings
Structural Rehabilitation
Industrial Floor Coatings
Structural Rehabilitation
Industrial Floor Coatings
Structural Rehabilitation
Industrial Floor Coatings
Structural Rehabilitation
Industrial Floor Coatings
Structural Rehabilitation
Industrial Floor Coatings
Structural Rehabilitation
Industrial Floor Coatings
To the product overview
Alexander Babajan - Management Quantec
ALEXANDER
BABAJAN
Managing Director
QUANTEC
Specialist company for industrial and warehouse floors
Landsberger Str. 70 - 06112 Halle (Saale)
+49 345 22589953
  • Sitemap
  • Legal Notice
  • Data protection
INDUSTRIEBÖDEN ® GmbH
Logo Quantec industrial floors
Your symptoms
The Quantec Solution
We will be happy to contact you.
File upload
Would you like a personal telephone consultation?